Test Date: 07/21/2008
Lab: Illinois (USA)
Part: Top Wing Post
Test Type: Chemical Composition / Hardness / Strength
Test Procedure: ASTM E415, E8 and E18.  A2LA Certified Testing.
Chemical tests to determine composition.
Rockwell Hardness test to determine hardness.
Tensile and Yield strength.
 

Chassis Tubing

 
 
Test/Sample ID

1" X 0.090

Carbon 0.29%
Manganese 0.48
Sulfur 0.008
Silicon 0.21
Chromium 0.83
Phosphorus 0.007
Molybdenum 0.17
Copper 0.09
Nickel <0.05
Rockwell Hardness HRC 25
Tensile Strength ksi 118.2
Yield Strength .2% offset ksi 111.4
Percent Elongation in 2.0" 7.6